Real Estate Software - ProGold i2 web site: www.progoldi2.com
Real Estate Search Engine - ViewMyListing.com web site: www.viewmylisting.com
Search Local Classifieds – www.viewmylisting.com/buy-sale-trade
Agent Tools web site: real estate agent software
Article ID: 4073
Subject: Pro Gold i2 Installation Guide for Microsoft Vista Operating System
Last Modified: January 22, 2013
Applies to: Pro Gold 2.xx, 3.xx
Summary: Pro Gold can be installed on a Microsoft Windows Vista Operating System. In order to receive the Vista compatible version, an upgrade may be necessary. To determine if you eligible for Pro Gold i2 / Vista contact Taro Systems at 1-888-500-9315 or email support@taronetwork.com
Document Index
Installation Overview page 2
Section A Obtaining Your Installation Files page 2
Section B Installing Pro Gold application page 3
Section C Creating and Installing Your SQL Database page 4
Software Activation page 6
Section D - Troubleshooting Installation Problems / Errors page 8
Installation Overview
Pro Gold i2 3.0 SQL platform for Windows XP, Vista Server 2003 R2, Server 2008, Operating Systems
Please read this entire document before starting your installation
Before you install your Pro Gold i2 Broker Management System, you must first determine your environment:
· Do your computers meet hardware requirements? Reference KBA article http://tkb.progoldxp.com/Showarticle.aspx?tkbid=40641
· What computer is going to host my Pro Gold i2 database? This computer will need to remain on in order for other Pro Gold workstation to connect to it.
· How many Pro Gold i2 installation I am licensed for. You can find your number of install license on your original purchase agreement.
· Internet connection required on all computers
With today’s security complexities we recommended that a qualified IT professional is available when installing applications for the first time.
The installation of Pro Gold i2 requires two procedures See section A and B
Refer to Section A: Obtaining Your Installation Files
Refer to Section B: Installing Pro Gold i2 software program on your PC.
This section will need to be repeated for all workstations that are licensed to use Pro Gold.
Refer to Section C: Creating and installing your SQL database.
This section only needs to be performed once on the computer you designated to host your Pro Gold i2 database.
Refer to Section D: Troubleshooting Installation Problems / Errors
Section A Obtaining Your Installation Files
Before you can begin your installation you must first either obtain a Pro Gold i2 installation CD or download the installation file from the Internet.
To order a Pro Gold i2 installation CD contact Taro Systems, Inc. at 616-940-0007 or email your request to support@taronetwork.com and include your contact information, mailing address and company information. There is a fee of $50.00 for a CD shipped ground or $75.00 for a CD shipped overnight.
To download your program installation file you must first create a folder on your c:\ drive. Label this folder ProGoldInstall Do NOT run or open this file you must first save it to your hard drive.
1) Create a folder on your hard drive C:\ and label it ProGoldInstall
2) Download the installation file by clicking the below link. Note when prompted DO NOT run or open the file. Save the file to the folder ProGoldInstall
http://www.taronetwork.com/pg2002/download/ProGoldi2Install.exe
Section B - Installing Pro Gold application
Installing Pro Gold software program on your PC. This section will need to be repeated for all workstations that are licensed to use Pro Gold.
Step 1 Login to your computer as the system administrator. The installation will not complete successful if you do not have administrative permissions to your computer. Contact your system administrator if needed.
Step 2 Prepare your system. - Close all open applications. Temporarily turn off any security applications that could prevent a successful install (firewall, anti-virus etc.) You will also want to make sure that your Internet security settings will allow:
FTP traffic to www.taronetwork.com
TCP Port 5500 – 6500
TCP Port 21
HTTP traffic to www.taronetwork.com
HTTP traffic to www.progoldi2.com
HTTP traffic to www.viewmylisting.com
HTTP traffic to www.progoldxp.com
Outbound SQL traffic TCP Port 1433
Pro Gold installs a runtime version of Microsoft Access version 2002. Higher versions of MS Access (i.e., 2003/2007) must be uninstalled prior to installing Pro Gold i2 and then re-installed once it is completed.
Step 3 Start the Installation Menu
If you’re installing from a CD – Insert the CD in your drive and the Installation menu will load. If the installation menu does not load start the autorun.exe manually from your CD.
If you are installing from a download installation file, start the installation menu by opening the ProGoldInstall.exe file. The installation menu may take a few minutes to extract and load.
Step 4 Install Pro Gold - Step 1 from the installation menu
Your system may require you to reboot your computer. If the installation does not resume after your system boots you will have to restart your installation
Step 5 Install Pro Gold Utilities - Step 2 from the installation menu
a. Select Next when prompted from the Installation Wizard
b. When prompted you can change location or accept the default. Make sure that Everyone is selected and select Next
c. Select Next to start the Pro Gold Utilities installation
d. When the installation is complete, select Close to return back to the Installation menu.
Step 6 Install FMS Memo - Step 3 from the installation menu
a. There is no user prompts installing this feature. Once the FMS Memo is installed the installation menu will load.
Section C - Creating and Installing Your SQL Database
Creating and installing your Pro Gold i2 database. This step only needs to be performed once on the computer you designated to host your Pro Gold i2 database. Before you can perform this step, you must first obtain a registered database name and key number.
Step 1 Send an email to support@taronetwork.com and request a database name and database create key. Your software purchase includes one database key. Multiple databases are available at a fee. Contact sales@taronetwork.com for additional databases.
Database Name ____________________________
Database Key ____________________________
Step 2 Record your exact computer name of the computer that will be hosting your database. _____________________________________
You can find your computer name by right clicking on the My Computer icon, select properties and select the Computer Name tab. The My Computer Icon can usually be found on your desktop or under your start menu.
Computer Name Example Frontdesk.mydomain.com
Frontdesk is your computer name
Step 3 Login to your computer as the system administrator. The installation will not complete successful if you do not have administrative permissions to your computer. Contact your system administrator if necessary.
Step 4 Step 2 Close all open applications. Temporarily turn off any security applications that could prevent a successful install (firewall, anti-virus etc.) You will also want to make sure that your Internet security settings will allow:
FTP traffic to www.taronetwork.com
TCP Port 5500 – 6500
TCP Port 21
HTTP traffic to www.taronetwork.com
HTTP traffic to www.progoldi2.com
HTTP traffic to www.viewmylisting.com
Outbound SQL traffic TCP Port 1433
Step 5 Start the Installation Menu
If you’re installing from a CD – Insert the CD in your drive and the Installation menu will load. If the installation menu does not load start the autorun.exe manually from your CD.
If you are installing from a download file, start the installation menu by opening the ProGoldInstall.exe file. The installation menu may take a few minutes to extract and load.
Step 6 Install Pro Gold SQL Data Engine (Data PC Only) - option 4 from the installation menu
Select the drive you wish to have your database stored on. The amount of disk space required depends on the amount of data you enter in Pro Gold. As a general rule you should always maintain 20 gig’s of free disk space on your drive at all times. The blank default database is less than 1 gig in size.
Once you select your drive to install the SQL data engine, the SQL database installation wizard will guide you through the process. Accept the default prompts. When finished you will return back to the installation menu.
Step 7 Create your Pro Gold i2 database
1. Start Pro Gold i2 as an administrator. To do this right click on your Pro Gold i2 icon from your start menu and select Run as Administrator. You only need to run Pro Gold as an administrator for the first time when creating your database.
2. If Pro Gold cannot find your database the New Company Database Utilities from will load and prompt your database connections information:
Server Name Enter your computer name or IP \ProGold from previous step 2
Example Frontdesk\ProGold
UserID Enter sa for the UserID when creating your database.
Enter ProGoldEnt once your database is created
Password ************ (preset by Pro Gold, do not change)
Database Name Enter your database name from previous step 1
Database Key Enter your database key from previous step 1
3. Once you enter the above information the Create DB button will be enabled allowing you to create your Pro Gold database and attach it to your SQL data engine.
4. If the Pro Gold i2 successfully creates your database you will be prompted to login or be prompted to install a newer version of Pro Gold.
Respond No if you do not have a current subscription to Taro Systems, Enhancement HelpNet Center or you wish to install your update at a later time.
Respond Yes if you do have a current subscription to Taro Systems, Enhancement HelpNet Center. When the update is finished you will be prompted to enter your Pro Gold User Name and Password.
A new database is not secured and does not have a password setup. Select Super as the User Name and click continue. You can setup your Pro Gold security at any time.
Pro Gold reserves the User Name Super as the systems administrative account. It is important that you establish a password for this account.
5. If Pro Gold i2 is unable to connect to your database more than likely you have security settings preventing Pro Gold to communicate with your SQL Pro Gold database. See Section C Troubleshooting Installation later described in this document.
Section D - Troubleshooting Installation Problems / Errors
Installation technical assistance is available through normal business hours.
Problem: You received an error when you try to install a newer version “Pro Gold could not download your file. Please try again. “
Cause: You have a Progold Utilities file conflict with Pro Gold
Resolution: Update Pro Gold from Pro Gold Utilities application.
1. Right click on the Pro Gold Utilities Icon in your system tray. If Pro Gold Utilities is not loaded in your system tray, start Pro Gold Utilities from your start menu.
2. Select the tab labeled Other and select download update.
3. When the Pro Gold logon screen appears, login to Pro Gold and verify that the program version and data version the same.
____________________________________________________________________________
Problem You received an error when you trying to connect to the database from the Database Utilities form “-2147467259 [DBNETLIB [ConnectionOpen(Connect)] SQL Server does not exist or access denied.”
Cause: The Pro Gold application cannot find nor has access to the SQL database.
Resolution: Verify the server name. The server name must be the computer name or IP of the computer hosting the Pro Gold SQL database. If you’re using an IP make sure that you use a static IP, or use the actual computer name if a static IP is not available. The convention for a standard database name using the default SQL data engine is: Computer Name\Progold
Resolution: Temporarily turn off all security such as fire walls, anti-virus on the computer that t is hosting your Pro Gold SQL database and try to re-connect. If this resolves the problem then you will need to configure your fire wall setting to allow connections on the SQL port 1433.
Resolution: Verify your User ID is either ProGoldEnt or sa
Resolution: Verify your Password; you will have to contact Taro Systems, Inc. to obtain this password. And only will be disclosed to the company owner.
Resolution: Verify your Database Name. If you do not know your database name you can do a Windows file search for the file ProGoldSQL_*.* on your hard drive of the computer that is hosting the database. When entering your database name on the Database Utilities form do not include the file extension.
Example database file ProGoldSQL_CN1000.mdf
Enter ProGoldSQL_CN1000 as your Database Name
Problem: Every time I start Pro Gold is prompts me to install a newer version even after answering yes.
Cause: Pro Gold has a version conflict with Pro Gold Utilities application or Pro Gold Utilities is not installed.
Resolution: Manually download your update by:
1. Start Pro Gold and answer No to install the newer version
2. Select Download Live Update from the Setup tab
3. Select Custom
4. Select from the drop down list PGUTILITIESINSTALL.EXE
5. Select Continue and follow the Pro Gold Utilities installation wizard through the install process.
6. Close Pro Gold
7. Open Pro Gold Utilities from your desktop icon or from your Windows start menu.
8. Select the “other” tab
9. Select Download Update. When the update is finished you will be prompted with your Pro Gold login information. Verify the program version and the data version are the same.
Problem: When I try to open Pro Gold from my Icon Pro Gold does not open.
Cause: You may have a version of Microsoft Office newer than the version Pro Gold. Microsoft requires that Office products including MS Access are installed oldest version first.
Resolution: Uninstall all MS Office and uninstall Pro Gold and reinstall Pro Gold before Installing MS Office 2003 or later versions.
____________________________________________________________________________
Problem: When I start Pro Gold I receive an 429 ActiveX component can’t create object Error.
Cause: You have a reference that is not installed or registered
Resolution: Re-install the FMS memo from the Installation menu option 3
Resolution: Uninstall Pro Gold Utilities from the Windows add/remove programs and Reinstall Pro Gold Utilities from the from the Installation menu option 2
Resolution: Manually register the reference file dao360.dll
1. Click on your Windows start button
2. Select Run and enter the command below and click OK
regsvr32 "C:\Program Files\Common Files\Microsoft Shared\DAO\dao360.dll"
If the dao360.dll is not located in the default location you will need to change the path to the location the dao360.dll is located in.
____________________________________________________________________________
Additional Information: Below is a link you can use to access Enhancement HelpNet Center resources, which includes the Knowledge Base Article (KBA) Library, Pro Gold i2 Documentation, and Training Webcasts:
http://secured.progoldi2.com/webcast.aspx
• The Enhancement HelpNet links are located on the right side of the web page.
Related articles: N/A
Keywords: Install, CD, Download, Connect, Standalone, LAN, Local Area Network, Installation, Re-Install
ActiveX, 429, Vista, 4073